Hotline: 090 905 8387 Email: [email protected]
Electrical calibration accessories

Fluke 5500A-COIL 50-Turn Current Coil

★ 0.0 (0 reviews)
Sold: 0
Views: 0

Fluke 5500A-COIL 50-Turn Current Coil supports the calibration of clamp-type current meters.

SKU: FLUKE 5500A-COIL
Stock status: Out of stock
Contact us for pricing and availability.
Description

Supports the calibration of clamp-type current meters

The 50 Turn 5500A/COIL is used as a tool for calibrating clamp type current meters that operate by two different principles -- as current transformers (AC only), and by the Hall Effect (Both AC and DC). It is impractical to calibrate 1000A rated current clamp meters using a 1000A source. However, by using the 50 turns of the 5500A/COIL in conjunction with a current calibrator you can effectively multiply the current of the current calibrator by a factor of 50 to support the calibration and verification of these clamp-on current meters.

Compatible products

Electrical calibration

  • Fluke 6003A
  • Fluke 5502A
  • Fluke 5520A
  • Fluke 5500A

Electrical calibrators

  • Fluke 5502E
  • Fluke 5522A
  • Fluke 5080A

Specifications

  • Number of turns: 50
  • Maximum current: 11 A rms, continuous, 20 A rms, 2 minutes
  • Maximum duty cycle derating: 11 A, 2 minutes ON, 8 minutes OFF
  • Maximum voltage: 3 V rms
  • Frequency of operation: DC, 45-440 Hz, should not exceed rms voltage rating
  • For the 5500A current output:
    • DC, 45-65 Hz, 0-11 A
    • 65-440 Hz, 0-2.19999 A
  • For the 5520A current output:
    • DC, 45-65 Hz, 0-20 A
    • 65-440 Hz, 0-2.99999 A
  • Uncertainty, toroidal clamps 80I, 80I-1000: ±(0.25% of effective output + 0.5 A)
  • Uncertainty, clamps 80i-kw, 80i-400: ±(0.50% of effective output + 0.5 A)
  • Uncertainty, clamps 80i-410, 80i-500: ±(0.50% of effective output + 0.5 A)
  • Uncertainty, clamps 80i-1010: ±(0.50% of effective output + 0.5 A)
  • Uncertainty, Fluke 31, Fluke 33: ±(0.50% of effective output + 0.5 A)
  • Calibration documentation:
    • Statement of calibration practices included
    • With 17025 accredited report
  • Minimum inside diameter of clamp jaws: 2.54 cm

Product reviews

Based on 0 reviews
0.0
Overall
5★ 0
4★ 0
3★ 0
2★ 0
1★ 0

Be the first to review “Fluke 5500A-COIL 50-Turn Current Coil”

🎁 Write a review to earn 20 reward points — photo +10, video +15.
Accumulate reward points to redeem unique gifts from Minh Khang Vinatools. Log in
Please log in to submit a review.
Recently viewed
No items yet
090 905 8387