Temperature calibrators

Fluke 5606-50-P Full Immersion PRT

★ 0.0 (0 reviews)
Sold: 0
Views: 0

Operate in temperatures ranging from -200 °C to 160 °C. Accuracy of ± 0.05 °C. Both the transition junction and lead wires of these PRTs can withstand the full PRT temperature range. Unique probe seal prevents moisture ingress. Come with NVLAP-accredited calibration. Suitable for calibration/validation of sensors in laboratory or bio freezers, autoclaves, ovens, test chambers, IQ/OQ/PQ qualification procedures, temperature mapping, and data logging in temperature-controlled spaces, and more.

SKU: FLUKE 5606-50-P
Stock status: Out of stock
Contact us for pricing and availability.
Description

Key features

  • Operate in temperatures ranging from -200 °C to 160 °C.
  • Accuracy of ± 0.05 °C.
  • Both the transition junction and lead wires of these PRTs can withstand the full PRT temperature range.
  • Unique probe seal prevents moisture ingress.
  • Come with NVLAP-accredited calibration.
  • Suitable for calibration/validation of sensors in laboratory or bio freezers, autoclaves, ovens, test chambers, IQ/OQ/PQ qualification procedures, temperature mapping, and data logging in temperature-controlled spaces, and more.

Total Flexibility for Extreme Environments

The Fluke 5606 Full Immersion Platinum Resistance Thermometer (PRT) offers an unmatched solution for applications where full immersion of the probe—including transition junction and lead wires—is required. With a compact length of just two inches (50 mm) and a sheath diameter of only 1/8 inch (3.1 mm), the 5606 delivers accuracy and durability in the tightest spaces.

Key Features and Benefits

  • Truly Full Immersion – No need to calculate minimum immersion depth. Simply immerse the entire probe, transition junction, and lead wires over the entire operating range—from –200 °C to 160 °C—in either non-corrosive liquids or dry mediums.
  • High Accuracy in a Compact Size – Achieve calibration accuracies as good as ±0.05 °C, thanks to the specially constructed 100 Ω precision sensing element (alpha = 0.00385) that also blocks moisture ingress.
  • Superior Moisture Protection – Single-conductor enameled copper lead wires prevent moisture from wicking into the sensing element, offering better protection than traditional stranded leads.
  • Flexible and Easy Installation – Lead wires measure no greater than 0.2 mm in diameter, making it simple to route through tight spaces—such as a freezer door—without energy loss.
  • Proven Durability – The 5606 has demonstrated excellent performance in heat transfer fluids like silicone oil, mineral oil, ethanol, and even liquid nitrogen, with no loss of integrity in the transition junction or lead wire insulation.

Engineered for Demanding Applications

The 5606 Full Immersion PRT is specifically designed to thrive in extreme environments. Both the transition junction and lead wires are built to endure temperatures covering the full probe range, ensuring complete reliability in challenging conditions.

“Immersion” means exposure to extreme temperatures—not just being submerged in a liquid—making the 5606 ideal for a wide variety of rigorous uses.

Manuals + resources


Specifications

  • Temperature range: -200 °C to 160 °C
  • Nominal resistance at 0.01 °C: 100 Ω ±0.1 Ω
  • Temperature coefficient: 0.00385 Ω/Ω/°C
  • Accuracy:
    • ±0.04 °C at 0.01 °C
    • ±0.06 °C at 160 °C
  • Short-term repeatability:
    • ±0.03 °C at 0.01 °C
    • ±0.04 °C at 160 °C
  • Drift:
    • ±0.03 °C at 0.01 °C
    • ±0.04 °C at 160 °C
  • Hysteresis: ±0.015 °C
  • Sheath length: 50 mm ±5 mm
  • Sheath diameter: 3.1 mm ±0.1 mm
  • Sheath material: 316 SST
  • Transition junction temperature range: -200 °C to 160 °C
  • Transition junction dimensions: No transition
  • Sensor length: 30 mm ±3 mm
  • Sensor location: 3 mm ±1 mm from tip
  • Minimum insulation resistance: 20 MΩ at 23 °C
  • Minimum immersion length: Full immersion
  • Maximum immersion depth in liquid medium: Full immersion
  • Maximum immersion depth in dry medium: Full immersion
  • Response time: 12 seconds typical, per ASTM E 644
  • Self heating: ±0.003 °C
  • Lead-wire cable type: Enameled copper wire
  • Lead-wire length: 2.4 meters
  • Lead-wire temperature range: 160 °C
  • Calibration:
    • Calibration not included
    • NVLAP accredited calibration available, see ordering information
  • Accuracy note: Includes calibration and 100 hr drift (k = 2)
  • Repeatability note:
    • Three thermal cycles from min to max temp, includes hysteresis
    • 95% confidence (k = 2)
  • Drift note:
    • After 100 hours at max temp
    • 95% confidence (k = 2)
  • Transition junction note: Temperatures outside this range will cause irreparable damage
  • At -197 °C:
    • 1924 calibration uncertainty 0.03 °C
    • tolerance without calibration 0.4 °C
  • At -38 °C:
    • 1924 calibration uncertainty 0.03 °C
    • tolerance without calibration 0.2 °C
  • At 0 °C:
    • 1924 calibration uncertainty 0.03 °C
    • tolerance without calibration 0.1 °C
  • At 100 °C:
    • 1924 calibration uncertainty 0.045 °C
    • tolerance without calibration 0.3 °C
  • At 157 °C:
    • 1924 calibration uncertainty 0.05 °C
    • tolerance without calibration 0.4 °C
  • Lab code: 200348-0
  • R0 value: Each PRT includes a certificate with a measured R0 value
  • Uncalibrated 5606: Meets ASTM E 1137 Grade A Classification of Tolerances
  • Grade A formula:
    • ±[0.13 + 0.0017|t|] °C
    • |t| = temperature in °C without regard to sign
  • Coefficient A: 3.9083 x 10^-3
  • Coefficient B: -5.775 x 10^-7
  • Coefficient C: -4.183 x 10^-12
  • Model 5606-50-P:
    • 50 mm probe
    • INFO-CON termination for 1523 or 1524

Product reviews

Based on 0 reviews
0.0
Overall
5★ 0
4★ 0
3★ 0
2★ 0
1★ 0

Be the first to review “Fluke 5606-50-P Full Immersion PRT”

🎁 Write a review to earn 20 reward points — photo +10, video +15.
Accumulate reward points to redeem unique gifts from Minh Khang Vinatools. Log in
Please log in to submit a review.
Recently viewed
No items yet