Current clamps

Fluke 80i-2010s AC-DC Current Clamp

★ 0.0 (0 reviews)
Sold: 0
Views: 0

Conveniently measure current without having to disconnect the load. 2,000A AC and DC current clamp. Maximum conductor size – 52mm (2.05in). Maximum opening – 81.5mm (3.2in).

SKU: FLUKE 80I-2010S
Stock status: Out of stock
Contact us for pricing and availability.
Description

Key features

  • Conveniently measure current without having to disconnect the load
  • 2,000A AC and DC current clamp
  • Maximum conductor size – 52mm (2.05in)
  • Maximum opening – 81.5mm (3.2in)

Available in packs of one, or as a three pack the Fluke 80i-2010s allows you to measure up to 2,000A AC and/or DC on large conductors with 0.8% accuracy. The 80i-2010S provides a convenient way to measure current without having to disconnect the load.

Manuals + resources

Compatible products

Adapters and cables

  • Fluke 17XX Clamp Adapter 1V
  • Fluke 17XX Clamp Adapter 2.8V

Power quality analyzers

  • Fluke Norma 6000

Specifications

  • Dimensions: 110 mm x 270 mm x 46 mm
  • Output cable:
    • 1.5 m shielded coaxial cable
    • BNC plug
  • Maximum conductor size: 52.0 mm
  • Maximum jaw opening: 81.5 mm
  • Output to zero: Auto adjustment with Zero button
  • Operating temperature: -10 °C to 50 °C
  • Storage temperature, battery removed: -30 °C to +60 °C
  • Operating humidity:
    • ≤ 90% RH at 10 °C to 30 °C
    • ≤ 75% RH at 30 °C to 40 °C
    • ≤ 45% RH at 40 °C to 50 °C
  • Operating altitude: 2,000 m
  • Storage altitude: 12,000 m
  • Demagnetize clamp: Open and close the jaws several times with soft click
  • Use on uninsulated conductors:
    • up to 1000 V AC rms or DC
    • frequencies 1 kHz or less
  • Safety:
    • IEC 61010-1, Pollution Degree 2
    • IEC 61010-2-032: CAT III 1000 V, CAT IV 600 V
  • Ingress protection: IEC 60529, IP40
  • Power supply: 2 x AA alkaline battery, IEC LR6
  • Battery life: 150 hours typical
  • Low battery indicator: Yes
  • Current range:
    • 2000 A AC rms
    • ±2000 A DC
  • Output sensitivity: 1 mV/A
  • Accuracy: ±0.8% of reading ±0.2% of range
  • Bandwidth for accuracy specification: DC to 400 Hz
  • Load impedance: >1 MΩ
  • Frequency response, small signal: DC to 20 kHz, -3 dB
  • Temperature coefficient:
    • 0.1 x specified accuracy per °C
    • above 28 °C or below 18 °C
  • Working voltage: 1000 V AC RMS or DC
  • Weight: 0.710 kg, including battery

Product reviews

Based on 0 reviews
0.0
Overall
5★ 0
4★ 0
3★ 0
2★ 0
1★ 0

Be the first to review “Fluke 80i-2010s AC-DC Current Clamp”

🎁 Write a review to earn 20 reward points — photo +10, video +15.
Accumulate reward points to redeem unique gifts from Minh Khang Vinatools. Log in
Please log in to submit a review.
Recently viewed
No items yet