Hotline: 090 905 8387 Email: [email protected]
Fiber optic testers

Fluke MultiFiber Pro MFTK1200 Optical Power Meter Base Kit

★ 0.0 (0 reviews)
Sold: 0
Views: 0

Automatic scanning and testing of all fibers in MPO connectors with "Scan All". Support for both Multimode and Singlemode MPO fiber trunks. Eliminates the need for fan-out cords when testing MPO fiber trunks. Easy to interpret test results with minimal navigation. The user interface displays all 12 fibers. Automatic 8, 10 and 12 fiber measurements. Troubleshoot MPO fiber links and drill down to single fiber test results.

SKU: FLUKE MFTK1200
Stock status: Out of stock
Contact us for pricing and availability.
Description

Key features

  • Automatic scanning and testing of all fibers in MPO connectors with "Scan All"
  • Support for both Multimode and Singlemode MPO fiber trunks
  • Eliminates the need for fan-out cords when testing MPO fiber trunks
  • Easy to interpret test results with minimal navigation
  • The user interface displays all 12 fibers
  • Automatic 8, 10 and 12 fiber measurements
  • Troubleshoot MPO fiber links and drill down to single fiber test results
  • Mag Kit Strap Attachment - Strong rare earth magnet attaches to metal surfaces in the testing environment, allowing the technician to work "hands free"

Introducing the MultiFiber Pro Optical Power Meter and Fiber Test Kits.

MultiFiber Pro Optical Power Meter and Source is the first fiber tester that can certify MPO fiber trunks without the use of fan-out cords. This single mode and multimode MPO fiber testing kit eliminates the complexity of polarity issues, and it makes cassettes easier to test in the field. Whether using 10 Gbps preterminated MPO fiber trunks or planning for next-generation 40/100 Gbps Ethernet performance, data centers are standardizing on an MPO connector solution. Typical data center fiber installation means time-consuming, manual, and imprecise MPO validation. MultiFiber Pro Optical Power Meter and Source is 90 percent faster than single fiber cable certification because it measures power loss and validates polarity on 12 fibers in a single connector - reducing test time from weeks to days.

"Scan All" Function

The Scan All function in the MultiFiber Pro Power Meter automatically scans and tests all 12 fibers in MPO connectors - taking just 6 seconds to complete all loss or power measurements. This feature automates the certification of MPO terminated fibers and eliminates the time consuming and manual process of moving the fiber tester from fiber to fiber while using fan-out cords.

Built-in Polarity Verification

The simple purpose of any polarity scheme is to provide a continuous connection from the link's transmitter to the link's receiver. For array connectors, TIA-568-C.0 defines three methods to accomplish this: Methods A, B and C. Deployment mistakes are common because these methods require a combination of patch cords with different polarity types. The polarity measurement of MultiFiber Pro allows the user to test individual patch cords, permanent links and channels for correct polarity.

On-board MPO Connector

Equipped with MPO connector on both the Optical Power Meter and Light Source, it eliminates the use of costly and complicated fan-out cords to test MPO fibers. Uncovered ports can put cabling, equipment and testers at risk for contamination and affect performance. Ensuring a covered connection on your tester can protect it from dirt and dust. MultiFiber Pro makes it easy by shuttering the MPO connector giving you greater test reliability and peace of mind.

Simple User Interface

The MultiFiber Pro is so successful at simplifying the task of simultaneously representing polarity, power and loss results for 12 fibers that the user interface is patent pending. The power meter enables the users to easily comprehend the measurement results of 12 fibers simultaneously. The light source identifies each fiber within the MPO connector that is being tested. Any individual measurement that fails the test limit is plainly identified to allow root-cause analysis. This powerful yet straightforward test set enables everyone to become a fiber testing expert and increases efficiency in testing data center projects.

Select an Individual Fiber

One of the main problems in the data center is the ability to drill down to a single fiber during testing and troubleshooting. MultiFiber Pro can troubleshoot a single fiber within an MPO trunk and provide a single fiber test result. This ability increases MPO connector verification and troubleshooting flexibility with more precise, per-fiber data and reporting.

Easy Reporting

The MultiFiber Pro Power Meter stores up to 3,000 test results (or the equivalent of 250 MPO cables) internally which can be uploaded to a PC using the LinkWare 7 Cable Test Management Software. LinkWare 7 allows you to manage test results, edit cable ID's, print professional reports and even export the data into spreadsheet formats.

Kits for Every Need

MultiFiber Pro is available in several convenient kit configurations to meet all your cleaning, inspection and verification testing needs. Some kits include: FI-7000 FiberInspector Pro with MPO tip and cleaning supplies.

The FI-7000 is the ultimate inspection tool. It enables you to quickly inspect and certify fiber end-faces inside ports or patch cords. It's 2-second automated PASS/FAIL eliminates human subjectivity and enables anyone to become a fiber inspection expert.

  • Automated Pass/Fail acceptance testing of fiber end-faces
  • Large touchscreen for pinch and zoom
  • Graphical indication of problem areas due to contamination, pits, chips, and scratches
  • Certify to industry standards - IEC 61300-3-35
  • Eliminate human subjectivity from end-face measurements
  • Includes MPO tip for inspection probe and MPO cleaner

Fiber Cleaning - Quick Clean Cleaners

Cleaning is critical. Fluke Networks' Quick Clean Cleaners instantly clean fiber optic bulkhead connectors and end-faces. Just push the tool tip to engage cleaning action and pull back on the wheel - it's that simple. The MPO Quick Clean Cleaner is bundled with the MultiFiber Pro kits to ensure that you have the best cleaning tool from the beginning.

What's in the box

  • MultiFiber Pro Power Meter
  • 850 Light Source
  • Test Cords
  • MPO adapters
  • Magnetic strap attachments
  • Carrying case

Manuals + resources


Specifications

  • Operating temperature: -10 °C to +50 °C
  • Storage temperature: -20 °C to +50 °C
  • Operating humidity, non-condensing:
    • 95%, 10 °C to 35 °C
    • 75%, 35 °C to 45 °C
    • uncontrolled < 10 °C
  • Operating altitude: 4,000 m
  • Storage altitude: 12,000 m
  • Vibration: Random 2 G, 5 Hz to 500 Hz
  • Optical Power Meter, at 23 °C
  • Detector type: InGaAs
  • Calibrated wavelengths: 850 nm, 1300 nm, 1310 nm, 1550 nm
  • Measurement range:
    • 0 dBm to -50 dBm at 850 nm
    • -5 dBm to -50 dBm at 1300, 1310, 1550 nm
  • Test time: 6 seconds
  • Power measurement linearity: ±0.1 dB, continuous-wave signal
  • Power measurement uncertainty: ±0.35 dB, continuous-wave signal
  • Power measurement repeatability: < 0.10 dB, continuous-wave signal
  • Display resolution: 0.01 dB or dBm
  • Power display units: dBm, mW, µW
  • User-selectable limit for loss:
    • 0.05 dB to 50.0 dB
    • 0.05 dB increments up to 10.0 dB
    • 0.1 dB increments up to 50.0 dB
  • Auto wavelength detection: Yes
  • Polarity detection: A, B, C, and Corning Plug & Play Universal Systems
  • 2 kHz detection: Yes
  • Record storage: 3000 records, one fiber per record, 250 12-fiber cables
  • External interface: USB 2.0, full speed
  • Optical connector:
    • MPO interface for 12-fiber, unpinned plugs
    • 62.5 µm, 50 µm and singlemode
    • self-closing protective cover
  • Meter power requirement: 2 AA alkaline batteries
  • Meter battery life: 30 hours typical, power levels ≤ 0 dBm, backlight on
  • Automatic power-off: 10, 20, 30, or 60 minutes, can be disabled
  • Low battery warning: Low battery icon blinks
  • Meter size: 14.7 cm x 8.0 cm x 4.0 cm
  • Meter weight: 309 g
  • 850 nm source:
    • LED
    • 850 nm ±30 nm
    • spectral width 50 nm typical
    • output ≥ -24 dBm
    • stability ≤ ±0.1 dB over 8 hours
    • at 23 °C after 10 min warm-up
  • 1310 nm source:
    • Laser
    • 1310 nm ±20 nm
    • spectral width 2 nm typical, 5 nm max
    • output ≥ -1 dBm
    • stability ±0.25 dB over 8 hours, 23 °C, 15 min warm-up
  • 1550 nm source:
    • Laser
    • 1550 nm ±20 nm
    • spectral width 2 nm typical, 5 nm max
    • output ≥ -1 dBm
    • stability ±0.25 dB over 8 hours, 23 °C, 15 min warm-up
  • Laser safety: IEC 60825-1, Class 1
  • 850 nm encircled flux:
    • TIA 455-526-14B, ISO/IEC 14763-3, IEC 61280-4-1
    • 50/125 µm at the source optical connector
  • 850 nm source connector:
    • MTP/MPO 12-fiber, unpinned plugs
    • 62.5 µm and 50 µm, non-APC only
    • self-closing protective cover
  • 1310 and 1550 nm source connector:
    • MTP/MPO 12-fiber, unpinned plugs
    • 9 µm, APC only
    • self-closing protective cover
  • Modes: 2 kHz modulated, auto wavelength
  • Source power requirement: 2 AA alkaline batteries
  • Source battery life: > 30 hours typical, Scan All and backlight on
  • Source size: 14.7 cm x 8.0 cm x 4.0 cm
  • Source weight: 323 g

Product reviews

Based on 0 reviews
0.0
Overall
5★ 0
4★ 0
3★ 0
2★ 0
1★ 0

Be the first to review “Fluke MultiFiber Pro MFTK1200 Optical Power Meter Base Kit”

🎁 Write a review to earn 20 reward points — photo +10, video +15.
Accumulate reward points to redeem unique gifts from Minh Khang Vinatools. Log in
Please log in to submit a review.
Recently viewed
No items yet
090 905 8387