Hotline: 090 905 8387 Email: [email protected]
Current clamps

Fluke Set of 3 5A/50A Current Clamps

★ 0.0 (0 reviews)
Sold: 0
Views: 0

Expand the capabilities of the Fluke 1735 and Fluke 1740 Series Loggers with the dual-range 5 A/50 A current clamps.

SKU: FLUKE MBX-CLAMP-5A-50A
Stock status: Out of stock
Contact us for pricing and availability.
Description

Expand the capabilities of the Fluke 1735 and Fluke 1740 Series Loggers with the dual-range 5 A/50 A current clamps. The accessory includes three precision clamps that are automatically detected and scaled by the instrument when attached.

Manuals + resources


Specifications

  • Nominal current In: 50 A AC rms
  • Overload: up to 100 A rms
  • Conductor position influence: < 0.5% of range at 50/60 Hz
  • Error due to adjacent conductor: ≤ 15 mA/A at 50 Hz
  • Phase shift at 2 kHz at 200 A: < ±1°
  • Frequency range: 40 Hz to 10 kHz (-3 dB)
  • Temperature coefficient: 0.015% of range/°C
  • Working voltage: 600 V AC rms or DC
  • Order reference:
    • 1-phase: EP0442A
    • 3-phase: EP0452A
    • 3-phase+N: EP0453A
  • Operating error at 0.125 A to 2.5 A: ±2.5% of reading
  • Phase shift at 0.125 A to 2.5 A: not specified
  • Operating error at 2.5 A to 12.5 A: ±1.5% of reading
  • Phase shift at 2.5 A to 12.5 A: < 2°
  • Operating error at 12.5 A to 25 A: ±0.5% of reading
  • Phase shift at 12.5 A to 25 A: < 0.5°
  • Operating error at 25 A to 50 A: ±0.5% of reading
  • Phase shift at 25 A to 50 A: < 1°
  • Maximum conductor size:
    • 15 mm diameter
    • bus bar 15 x 17 mm
  • Cable length: 2 m
  • Operating temperature range: -10 °C to +55 °C
  • Storage temperature range: -20 °C to +70 °C
  • Operating humidity: 15% to 85% RH, non condensing
  • Environment temperature range: +18 °C to +26 °C
  • Humidity: 20% to 75% RH
  • Current:
    • sinusoidal waveform, 48 to 65 Hz
    • distortion factor < 1%, no DC component
  • Load impedance for voltage output: ≥ 1 MΩ, < 100 pF
  • Safety standards:
    • IEC/EN61010-1: 2001
    • IEC/EN61010-2-032
    • IEC/EN61010-2-031
  • Safety: 600 V CAT III, pollution degree 2
  • Uninsulated conductors limit:
    • 600 V rms or DC to ground
    • frequencies below 1 kHz
  • EMC standards: EN61326-1: 1997/A1: 1998
  • Dimensions: 102 x 42.5 x 23.5 mm
  • Weight per clamp: 175 g

Product reviews

Based on 0 reviews
0.0
Overall
5★ 0
4★ 0
3★ 0
2★ 0
1★ 0

Be the first to review “Fluke Set of 3 5A/50A Current Clamps”

🎁 Write a review to earn 20 reward points — photo +10, video +15.
Accumulate reward points to redeem unique gifts from Minh Khang Vinatools. Log in
Please log in to submit a review.
Recently viewed
No items yet
090 905 8387